869 reviews analysed
1. Aube RC840T-240 On/Off Switching Electric Heating Relay with Built-in 24 V Transformer
Description
honeywell rc840t-240 electromechanical 22 a 5280 w built-in transformer 208-240/24 v
2. Dorhea STC-1000 Digital Temperature Controller AC 10A 110V-220V Digital LED Temperature Controller Heating Cooling Centigrade Thermostat 2 Relays Output with NTC Sensor Probe(110V/220V)
Feature
- 100% brand new and high quality
- Mini and light weight design
- large and clear LCD display.
- Auto converts cooling and heating modes to keep your equipment in an ideal temperature range. .Have 2 relays .Switch between cooling and heating modes. Support celsius display.
- Wide temperature range (-50-99 °C)
- dual heating and cooling function.
- Refrigerating control output delay protection
- With compressor delay protection function for refrigerating control.
- Control temperature by setting the temperature set value and the different value.
Description
Resolution: 0.1 °C; Accuracy: ± 1 °C (-50 ° C ~ 70 ° C)
Power Supply: 110~ 220V AC ± 10% , 50 / 60 Hz
Power Consumption: <>
Operating Relative Humidity: 20% ~ 85% (No condensate)
Compressor Delay Protection Time: 1 ~ 10 minutes (adjustable)
Cable Length: 1 M
Sensor: NTC Sensor
Sensor Error Delay: 1 minute
Relay Contact Capacity (Heating): 10A (max) 250V
Relay Contact Capacity (Cooling): 10A (max) 250V
Operating Temperature: 0 ° C ~ 60 ° C°
Storage Temperature: 30 ° C ~ 75 ° C
Temperature Measuring Range : -50 ° C ~ 99 ° C(adjustable)
Package Included:
1x Digital Temperature controller 110v-220V
1 x Temperature sensor
3. Baomain 3 Phase Solid State Relay JGX-3340A 3-32 VDC Input 480VAC 40 Amp Output DC/AC
4. Aprilaire 50 Sensing Relay, 24-volt
Description
Product Description
Current sensing relay used to turn Aprilaire humidifiers on when indoor blower of air handler is energized. Makes installing any humidifier easier than ever before.
From the Manufacturer
Current sensing relay used to turn Aprilaire humidifiers on when indoor blower of air handler is energized. Makes installing any humidifier easier than ever before.
5. TWTADE SSR-40VA 500K ohm 1/4W to 24-380VAC 40A Single Phase Solid State Relay Resistance Voltage Regulator Authorized+Heat Sink+potentiometer+A knob
Feature
- Specifications: This is solid state relay SSR-40VA.
- Input Resistance/Power: 500Kohm/2W Output voltage: 24-380V AC
- Heat Sink Mounting Thread Diameter (Approx.) : 0.5cm / 0.19″
- Heat Sink Total Size (Approx.) : 8 x 4.9 x 4.9cm / 3.1″ x 1.9″ x 1.9″ (L * W * T )
- Package Content: 1 x SSR, 1 x heat sink, 1 x 470Kohm potentiometer ,1 x knob
Description
Feature: High reliability,high efficiency and long lifespan. No electric spark,no noise and no contact. Fine electro magnetic interference,high sensitivity and fast switching speed. Low drive voltage and current. Unique shape and novel structure. Especially suitable for corrosion, moisture,dust resistant and other harsh environments. Widely used in many automatic control systems. Specifications: This is solid state relay SSR-40VA. Model: SSR-40VA Input Resistance/Power:500Kohm/2W Output voltage: 24-380V AC Output current: 40A Control Mode:External Controlling Potentiometer Insulation Resistance:1000M ohm/500VDC Ambient Temperature:-30C – +75C Protection Character:Resin Soldering Off Leakage Current: less or equal to 2mA Mounting Method: Bolts Fixed Relay size: 44.8 x 57.4 x 28mm/1.76×2.25×1.1inch(L*W*H) Weight:110g
6. Supco 90380 General Purpose Fan Relay, 13 A Load Current, 24 V Coil Voltage, Normally Open and Normally Closed Contacts
Description
The Supco 902 series fan relays receive and control electrical signals for general purpose fan applications. This fan relay has SPST-NO, SPST-NC, SPDT-NO/NC contacts made of silver alloy and coil voltage ratings of 24VAC to 240VAC. It is suitable for use in fan applications.
Specifications
Contacts | SPST-NO, SPST-NC, SPDT, 1 NO/1 NC |
Contact material | Silver alloy |
Power ratings (all forms) | 125VAC, 18 amp resistive, 12 FLA, 60 LRA, 240/277VAC, 18 amp resistive, 8 FLA, 48 LRA |
Special power ratings (form 1 and 2) | 125VAC, 14 FLA, 84 LRA, 277VAC, 25 amp resistive |
Pilot ratings (all forms) | 3 amp, 277VAC general purpose 250VA at 250VAC 277VA at 277VAC 125VA at 125VAC |
Coil voltage rating | 24, 120, 208/240, 77VAC, 12, 24 |
Coil frequency | 50/60 Hz |
Coil pick-up voltage | AC 85% of nominal, DC 75% of nominal |
Coil power rating | AD DC, Inrush 5VA 3VA, Sealed 3VA 3VA |
Relay switches (also called an electrical relay or an electrical relay switch) use a small amount of power to control a larger source of power connected to electrical devices such as car motors, computers, and lighting installations. A basic relay switch has a control circuit with an electromagnetic coil and a load circuit with contacts and a lever. When current flows into the relay switch, it moves through the coil and a magnetic field is created, which causes the lever in the load circuit to move between contacts, either turning the device on or off. In a normally open (NO) relay switch, when power is supplied to the relay, the load circuit is closed and the power source connected to the relay is turned on. In a normally closed (NC) relay switch, when power is supplied to the relay, the load circuit is open and the power source connected to the relay is turned off. In other types of relay switches, non-moving parts such as transistors or semiconductors can be used as the control circuit to operate the switching mechanism. Relay switches can be controlled with an external switch, such as a light switch, or they can be connected to an automatically switched power source, such as a car ignition. One relay can operate multiple switches, and multiple relays can be operated with a single switch, with each relay operating independently from the other relays in the system.
Supco manufactures test instruments and replacement parts for heating, ventilation, air conditioning, and refrigeration systems. The company, founded in 1945, is headquartered in Allenwood, NJ.
7. uxcell Heat Sink + Solid State Relay SSR-25 DA 25A 3-32V DC / 24-380V AC
Description
Feature:
1. High reliability, high efficiency and long lifespan
2. No electric spark, no noise and no contact
3. Fine electro magnetic interference, high sensitivity and fast switching speed
4. Low drive voltage and current
5. Unique shape and novel structure
6. Especially suitable for corrosion, moisture, dust resistant and other harsh environments
7. Widely used in many automatic control systemsSpecification:This is solid state relay SSR-25DA.Model: SSR-25DAInput voltage: 3-32V DCOutput voltage: 24-380V ACOutput current: 25ABrand: Uxcell
Matters Needing Attention:
1. The current on the product is the maximum load current, not the rated current.
2. On the basis of the different of the load character,you should keep the different allowance on the level of the current when you choose the product.(When the load is resistive, the load current should be 1/2-1/3 times of the max load current .When the load is inductive or capacitive,like motor, transformer, the load current should be 1/4-1/6 times of max load current.)
3. When Installation,solid state plater and radiator with smeared thermal conductivity silicone grease
4. ≥10A With radiator, ≥20A with radiator and fan strong cold.
8. INKBIRD 40A SSR Solid State Relay SSR-40DA 3-32V DC tO 24-380V AC
Description
Note: A heatsink must be used or it will get burned out.
For sale is a 40A Solid State Relay (SSR). It’s good for heater, oven, or other appliance up to 3500Watt power consumption. Ideal for PID temperature controller.
Specification
Input: 3V-32V DC
Control: 24V~380V AC
Current: 40A
Packge:
1 x solid state relay 40A
9. TWTADE SSR-25 DA 25A 3-32V DC / 24-380V AC Solid State Relay + Heat Sink
Feature
- Special attention: The current of this product is 10A for a long time.A large heat sink or fan need to be added.Model: SSR-25DA Solid State Relay 25A DC to AC
- Input voltage: 3-32V DC Output voltage: 24-380V AC
- Heat Sink Mounting Thread Diameter (Approx.) : 0.5cm / 0.19″
- Heat Sink Total Size (Approx.) : 8 x 4.9 x 4.9cm / 3.1″ x 1.9″ x 1.9″ (L * W * T )
- Package Content: 1 x SSR, 1 x heat sink
Description
1. High reliability, high efficiency and long lifespan 2. No electric spark, no noise and no contact 3. Fine electro magnetic interference, high sensitivity and fast switching speed 4. Low drive voltage and current 5. Unique shape and novel structure 6. Especially suitable for corrosion, moisture, dust resistant and other harsh environments 7. Widely used in many automatic control systems Specification: This is solid state relay SSR-25DA. Model: SSR-25DA Input voltage: 3-32V DC Output voltage: 24-380V AC Output current: 25A Brand: TWTADE
10. DZS Elec DC 6.0-30V Digital Temperature Controller Switch 12V 24V -50 to 110 Celsius LCD Temperature Monitoring Instrument Heating/Cooling Auto Switch AC 220V 10A High Temperature Buzzes Alarm
Feature
- LCD Temperature Control Monitoring Instrument, Heating H / Cooling C two kinds of working mode, 0.1 Celsius high precision control, with 10K0.5£¥NTC T-sensor.
- Temperature Controller Switch Module, wide operating voltage range: DC 6.0-30V, temperature control range: -50 to 110 Celsius. Compatible with the control of AC 220V 10A load.
- Clear data display: LCD displays the current detection temperature, setting temperature, working mode, output state of relay, and whether to open delay start multiple digital information, which can directly obtain the current working state.
- Protection: With protective casing, one key emergency stop, power lost memory and high temperature alarm function, support to restore factory Settings, serial port TTL level communication remote control.
- Programmable functions: high temperature alarm, delayed start, temperature correction, UART remote reading/setting parameters, real-time temperature reporting, relay enabling
- Can be widely used in smart home, industrial control and so on.
Description
Product Description:
Name: Digital Temperature Control Monitoring Instrument
Operating Voltage: DC 6.0-30V
Temperature Control Range: -50 to 110 Celsiu
Control Accuracy: 0.1 Celsius
Refresh Rate: 0.5s
T-Sensor Type: 10K0.5%NTC
Compatible Load: DC 6.0-30V or AC 220V 10A
Protection Function: Support one key emergency stop and power lost memory
Restore Factory Defaults:
Press the STOP and SET buttons above 3S at the same time to restore the factory setting.
High temperature alarm (ALA) function:
The actual temperature is greater than the alarm temperature, open the sound-light alarm, disconnect the relay, and press any key to stop the alarm.
Delayed start (OPH) function:
After completing a normal heating/cooling operation, start timing T, and carry out the next round of heating/cooling when T is greater than OPH.
Temperature correction (OFE) function:
Calibration value range – 10 to 10 Celsius, the actual temperature = measuring temperature + calibration value
Programming setting:
Working mode/temperature setting/return difference temperature
1. Short press SET key to enter the quick setting interface;
2. Switch to set the parameter value by short press SET, UP/DOWN to modify.
Alarm temperature/delay start/temperature correction:
1. Long press SET key for 3s to enter the parameter setting interface;
2. Switch to set the parameter value by short press SET, UP/DOWN to modify, STOP to open or close.
Long press SET key 3S above or 6S, no operation to exit setting and save parameters.
Tips:
UP/DOWN supports short press or long press to rapidly increase or decrease;
UART serial port control (single-chip TTL level communication) order details can be found in the product photo.
Package Include:
1pc DC 6.0-30V LCD Digital Temperature Controller
Conclusion
By our suggestions above, we hope that you can found 220V Heating Relay 24Volt for you.Please don’t forget to share your experience by comment in this post. Thank you!